§ 171.319. Approach elevation monitor system requirements.

295 words·~1 min read·/us/cfr/t14/s§ 171.319·

A research copy — for the controlling text, always check the official state or federal source. Not legal advice.

(a)The monitor system must act to ensure that any of the following conditions do not persist for longer than the periods specified when:
(1)There is a change in the ground component contribution to the mean glidepath error component such that the path following error on any glidepath exceeds the limits specified in § 171.317(d) for a period of more than one second. Note: The above requirement and the requirement to limit the ground equipment mean error to ±0.067 degree can be satisfied by the following procedure. The integral monitor alarm limit should be set to ±0.067 degree. This will limit the electrical component of mean glidepath error to ±0.067 degree. The field monitor alarm limit should be set such that with the mean glidepath error at the alarm limit the total allowed PFE is not exceeded on any commissioned glidepath from the limit of coverage to an altitude of 100 feet.
(2)There is a reduction in the radiated power to a level not less than that specified in § 171.317(a)(4) for a period of more than one second.
(3)There is an error in the preamble DPSK transmission which occurs more than once in any one second period.
(4)There is an error in the time division multiplex synchronization of a particular elevation function such that the requirement specified in § 171.311(e) is not satisfied and this condition persists for more than one second.
(5)A failure of the monitor is detected.
(b)The period during which erroneous guidance information is radiated must not exceed the periods specified in § 171.319(a). If the fault is not cleared within the time allowed, radiation shall cease. After shutdown, no attempt must be made to restore service until a period of 20 seconds has elapsed.
★   the supreme law of the land   ★
Don't Tread on Me
E Pluribus Unum — out of many, one

"If you don't know your rights, you don't have any."

Marginalia · a citizen's law index
A research desk, not legal advice. Always read the cited source before relying on a summary.
Questions or an issue? support@self-law.org
disclaimerMarginalia is a research index, not a law firm. Nothing on this site is legal, tax, or financial advice and no attorney–client relationship is formed by using it. Statutes, regulations, and case law change; summaries, search results, AI output, and member posts may be incomplete, out of date, or wrong. Any interpretation drawn from material on this site should be validated by a licensed attorney in your jurisdiction before you act on it.